Ò»¡¢ÅäÖÃǰµÄ×¼±¸£º¿ªÆôVROC

×¢Ò⣺ÐèÒªÏȰÑbiosÏÂģʽͳһÐ޸ijÉUEFIģʽ¡£

µÇ¼µ½BIOS Setup½çÃæ£¬Ñ¡Ôñ¡°Advanced?CSM Configuration¡±½çÃæ£¬°´Enter¼ü£¬¶ÔBoot Mode Ñ¡Ïî½øÐÐÉèÖ㬿ɶÔϵͳµÄÆô¶¯Ä£Ê½£¨UEFI Mode/Legacy Mode£©½øÐÐÉèÖò¢ÏàÓ¦ÉèÖÃNetwork£¬Storage£¬Video Oprom Policy£¬Other PCI devicesµÄOption ROM µÄÖ´Ðз½Ê½,ÈçÏÂͼ5¸öÑ¡ÏîͳһÐ޸ijÉUEFI.

Ŀǰintel VROC½öÖ§³Öbios½çÃæÏÂÅäÖÃraid

Ê×ÏÈ£¬ÔÚÅäÖÃ֮ǰÐèÒªÏÈÐÞ¸ÄVMD configuration

Processor > IIO Configuration> Intel(R) VMD Technology

ÒÔNF5280M5ΪÀý£¬nvme½Ó¿ÚΪCPU1Ö§³Ö£¬ËùÒÔÐèÒªÐÞ¸Ä

Intel(R) VMD for volume Management Device on socket 1


ÆäÖС±PStack0¡å ºÍ ¡°PStack1¡å¶¼ÐèÒªÉèÖÃΪdisable, ¡°PStack2 ¡°ÐèÒªÉèÖÃΪenable ÆäËû²ÎÊýĬÈÏ


ÅäÖÃÍê³Éºóf10±£´æÖØÆô

¶þ¡¢RAIDÅäÖÃÓë¹ÜÀí

1¡¢²é¿´ÕóÁÐ

AdvacnedÏÂIntel(R) Virtual RAID on CPU

RAIDÅäÖÃ-²é¿´ÕóÁÐ

Ñ¡ÔñÒª²é¿´µÄÕóÁÐ


»Ø³µºó¿ÉÒÔ¿´µ½ÕóÁÐÏà¹ØÐÅÏ¢ºÍ³ÉÔ±ÅÌ


2¡¢É¾³ýÕóÁÐ

AdvacnedÏÂIntel(R) Virtual RAID on CPU

ÔÚIntel VROC Managed Vloumes Ï¿ÉÒÔ¿´µ½µ±Ç°´´½¨µÄraidÁбí

Ñ¡ÖÐÐèҪɾ³ýµÄraid»Ø³µ½øÈë


Ñ¡ÖÐdelete»Ø³µ


Ñ¡Ôñyes ɾ³ýraid£¨×¢Òâɾ³ýraidºóraidϵÄÊý¾Ý¶¼»á±»Çå³ý£¬½÷É÷²Ù×÷£©


3¡¢ÅäÖÃraid0

AdvacnedÏÂIntel(R) Virtual RAID on CPU

Ñ¡ÔñALL Intel VMD Controllers

ÅäÖÃraid0

´Ëʱ¿ÉÒÔ¿´µ½Non-RAID physicalÏÂÓÐδÅäÖÃraidµÄÎïÀí´ÅÅÌÐÅÏ¢

Ñ¡Ôñ Create RAID Volume


Name£ºÃû×Ö£¨×Ô¶¨ÒåÒ²¿ÉÒÔʹÓÃĬÈÏ£©

RAID Level£ºraid¼¶±ð

Enable RAID spanned over VMD Controllers: ¿çÔ½VMD¿ØÖÆPGµç¾º¹ÙÍø´´½¨ÕóÁУ¨Ä¬Èϲ»¹´Ñ¡£©

Select Disks: Ó²ÅÌÁбí

NameĬÈϼ´¿É£¬raid levelÑ¡ÔñRAID0


Select disks Öпոñ¹´Ñ¡ÐèÒªÌí¼Óµ½raid×éÖеÄÓ²ÅÌ


Strip size Ìõ´øÖµÒ»°ãĬÈϼ´¿É

Capacity (GB) ÈÝÁ¿Ä¬ÈÏ·Ç×î´óÈÝÁ¿£¬¿É²Î¿¼maximum ÉèÖÃ×î´óÈÝÁ¿Ò²¿É×Ô¶¨ÒåÈÝÁ¿£¬Èç·Ç×î´óÈÝÁ¿£¬Ê£Óà¿Õ¼ä¿ÉÔٴδ´½¨raid


Ñ¡ÔñCreate Volume ¼´¿É´´½¨³É¹¦


4¡¢ÅäÖÃraid1

×¢Ò⣺ĿǰVROCĬÈÏÖ§³Öraid0£¬ÈçÐèÅäÖà raid1¡¢10¡¢5ÐèÒªÖ÷°å¼Ókey

AdvacnedÏÂIntel(R) Virtual RAID on CPU

Ñ¡ÔñALL Intel VMD Controllers

ÅäÖÃraid1

´Ëʱ¿ÉÒÔ¿´µ½Non-RAID physicalÏÂÓÐδÅäÖÃraidµÄÎïÀí´ÅÅÌÐÅÏ¢

Ñ¡Ôñ Create RAID Volume


Name£ºÃû×Ö£¨×Ô¶¨ÒåÒ²¿ÉÒÔʹÓÃĬÈÏ£©

RAID Level£ºraid¼¶±ð

Enable RAID spanned over VMD Controllers: ¿çÔ½VMD¿ØÖÆPGµç¾º¹ÙÍø´´½¨ÕóÁУ¨Ä¬Èϲ»¹´Ñ¡£©

Select Disks: Ó²ÅÌÁбí

NameĬÈϼ´¿É£¬raid levelÑ¡ÔñRAID1

Select disks Öпոñ¹´Ñ¡ÐèÒªÌí¼Óµ½raid×éÖеÄÓ²ÅÌ


Capacity (GB) ÈÝÁ¿Ä¬ÈÏ·Ç×î´óÈÝÁ¿£¬¿É²Î¿¼maximum ÉèÖÃ×î´óÈÝÁ¿Ò²¿É×Ô¶¨ÒåÈÝÁ¿£¬Èç·Ç×î´óÈÝÁ¿£¬Ê£Óà¿Õ¼ä¿ÉÔٴδ´½¨raid

Ñ¡ÔñCreate Volume ¼´¿É´´½¨³É¹¦


5¡¢ÅäÖÃraid5

×¢Ò⣺ĿǰVROCĬÈÏÖ§³Öraid0£¬ÈçÐèÅäÖà raid1¡¢10¡¢5ÐèÒªÖ÷°å¼Ókey

AdvacnedÏÂIntel(R) Virtual RAID on CPU

Ñ¡ÔñALL Intel VMD Controllers

ÅäÖÃraid5

´Ëʱ¿ÉÒÔ¿´µ½Non-RAID physicalÏÂÓÐδÅäÖÃraidµÄÎïÀí´ÅÅÌÐÅÏ¢

Ñ¡Ôñ Create RAID Volume


Name£ºÃû×Ö£¨×Ô¶¨ÒåÒ²¿ÉÒÔʹÓÃĬÈÏ£©

RAID Level£ºraid¼¶±ð

Enable RAID spanned over VMD Controllers: ¿çÔ½VMD¿ØÖÆPGµç¾º¹ÙÍø´´½¨ÕóÁУ¨Ä¬Èϲ»¹´Ñ¡£©

Select Disks: Ó²ÅÌÁбí

NameĬÈϼ´¿É£¬raid levelÑ¡ÔñRAID5

Select disks Öпոñ¹´Ñ¡ÐèÒªÌí¼Óµ½raid×éÖеÄÓ²ÅÌ


Strip size Ìõ´øÖµÄ¬Èϼ´¿É

Capacity (GB) ÈÝÁ¿Ä¬ÈÏ·Ç×î´óÈÝÁ¿£¬¿É²Î¿¼maximum ÉèÖÃ×î´óÈÝÁ¿Ò²¿É×Ô¶¨ÒåÈÝÁ¿£¬Èç·Ç×î´óÈÝÁ¿£¬Ê£Óà¿Õ¼ä¿ÉÔٴδ´½¨raid


Ñ¡ÔñCreate Volume ¼´¿É´´½¨³É¹¦


6¡¢ÅäÖÃÈȱ¸ÅÌ

AdvacnedÏÂIntel(R) Virtual RAID on CPU

Ñ¡ÔñALL Intel VMD Controllers

ÅäÖÃÈȱ¸ÅÌ

ÔÚNon-RAID physical¿ÉÒÔ¿´µ½Î´ÅäÖôÅÅÌ£¬Ñ¡ÖÐÕâ¿éÅ̻سµ


Ñ¡Ôñmark as Spare


Ñ¡Ôñyes»Ø³µ


´Ëʱ²é¿´¸ÃÅÌ״̬£¬ÒѾ­ÊÇSpare Èȱ¸ÅÌ


Èý¡¢³£¼ûÎÊÌâ

1£®ÎÞ·¨ÅäÖÃraid 0¡¢raid1¡¢5¡¢10

ÈôÎÞÅäÖÃraidÑ¡Ï»òÕßÖ»ÄÜÅäÖÃraid0,¶ø²»ÄÜÑ¡ÔñÀ©Õ¹raid,ÈçÐèÖ÷°åÐè¼Ókey

ÈçÏ¡±RAID_KEY¡±Î»ÖÿÉÒÔ°²×°NVMEµÄRAID KEY£¬Èç¹û²»°²×°VROCÖ»ÄÜ×öRAID0£¬°²×°ÁË¿ÉÒÔ×öÆäËûÀ©Õ¹RAID¡£


2£®µ¥Å̵ôÏß

µ±ÅäÖÃraid1¡¢5¡¢10ʱµ¥Å̵ôÏßÕóÁлáÌáʾ½µ¼¶degraded


¸ü»»ÐµÄÓ²Å̺ó»á×Ô¶¯rebuilding


Èç¹ûûÓÐ×Ô¶¯rebuildingÒ²¿ÉÒÔÔÚÅäÖýçÃæÏÂÊÖ¶¯rebuildÉÏÏßÓ²ÅÌ

Ñ¡ÔñÕóÁлسµ


Ñ¡ÔñRebuild»Ø³µ


Ñ¡ÖÐÐèÒªÉÏÏߵĴÅÅ̻سµ


»Ø³µºóÕóÁÐrebuilding


ÖØ½¨Íê³ÉºóÕóÁÐNormal״̬


3£®¶àÅ̵ôÏß

¶àÅ̵ôÏߣ¬ÕóÁÐfailed״̬£¬´ËʱÕóÁÐÒѲ»¿ÉÓã¬ÈçÊý¾ÝÖØÒª½¨ÒéѰÇóÊý¾Ý»Ö¸´»ú¹¹Ö§³Ö