Ò»¡¢RAID¿¨ÕóÁÐÅäÖÃ
1.1½øÈëraid¿¨ÅäÖýçÃæ
¿ª»úÔÚlogo½çÃæ°´del¼ü½øÈëbios½çÃæ

Ñ¡Ôñadvanced-csm configuration

Ôڴ˽çÃæ½«boot modeµÈ5ÏîÐÞ¸ÄΪlegacyģʽ£¬F10±£´æÖØÆô

·þÎñPGµç¾º¹ÙÍø¿ª»ú¹ý³ÌÖÐÔÚ³öÏÖctrl+a×ÖÑùºó£¬Ôڴ˽çÃæ°´ctrl+a¼´¿É½øÈëraid¿¨ÅäÖýçÃæ

raid¿¨ÅäÖýçÃæÈçÏÂͼ

1.2²é¿´RAIDÕóÁÐ
Ñ¡Ôñarray configuration

Ñ¡Ôñ manage arrays

¿ÉÒԲ鿴Ŀǰ´æÔÚµÄÕóÁУ¬¼ÌÐø»Ø³µ²é¿´ÕóÁÐ

¿ÉÒÔ¿´µ½ÕóÁм¶±ðºÍ´óС

¼ÌÐøÑ¡Ôñ»Ø³µ¿ÉÒԲ鿴ÕóÁеÄÏêϸÐÅÏ¢£¬ctrl+d¿ÉÒԲ鿴ÕóÁÐĿǰ´æÔÚµÄÓ²ÅÌ

1.3ɾ³ýRAIDÕóÁÐ
Ö÷½çÃæÑ¡Ôñarray configuration

µã»÷manage array

ctrl+dɾ³ýÕóÁÐ

°´YÈ·ÈÏ

1.4RAID0µÄÅäÖÃ
Ñ¡Ôñarray configuration

µã»÷create array

¿ÉÒÔ¿´µ½Ä¿Ç°´æÔÚµÄÓ²ÅÌ£¬µã»÷insÑ¡ÔñÒª×öÕóÁеÄÓ²ÅÌ

Ñ¡ÔñÍê³Éºóµã»÷»Ø³µ

ÕóÁм¶±ðÑ¡Ôñraid0£¬logical drive name¶ÔÕóÁнøÐÐÃüÃû£¬ÆäËû½¨ÒéĬÈÏ£¬¾ßÌå²ÎÊýº¬ÒåÈçÏÂ±í£¬Ñ¡ÔñÍê±Ïºóµã»÷done

| ²ÎÊý | ˵Ã÷ |
| RAID Level | RAIDµÄ¼¶±ð¡£ |
| Logical Drive Name | RAIDµÄÃû³Æ¡£ |
| Strip Size/Full Stripe Size | Strip Size£ºµ¥¸öÎïÀíÅ̵ÄÌõ´ø´óС£¬¿ÉÉèÖÃΪ16KiB/32KiB/64KiB/128KiB/256KiB/512KiB/1024KiB£¬Ä¬ÈÏֵΪ256KiB¡£ |
| Parity Group Count | PGCµÄ¸öÊý¡£ ¸ÃÑ¡ÏîÖ»ÔÚ´´½¨RAID 50ºÍRAID 60ʱÓÐЧ£¬´´½¨ÆäËû¼¶±ðµÄLDʱÎÞЧ¡£ PGC±íʾLDÖеÄ×Ó×éÊý£¬ÈçRAID 50ÓÉÁ½¸öRAID 5×é³É£¬ÔòPGCÏÔʾΪ¡±2¡å¡£ |
| Build Method | УÑé³õʼ»¯µÄ·½·¨¡£ Defult£ºÔÚÏß½øÐкǫ́УÑé³õʼ»¯£¬Ñ¡Ôñ¸ÃģʽµÄLD»áÁ¢¼´Éϱ¨¸øOS£¬ÔÚºǫ́½øÐÐУÑé³õʼ»¯£¬¶ÔÐÔÄÜÓÐÒ»¶¨³Ì¶ÈµÄÓ°Ïì¡£ RPI£ºÀëÏß½øÐпìËÙ³õʼ»¯£¬³õʼ»¯Íê³Éºó²Å»áÉϱ¨¸øOS¡£ ˵Ã÷£º ¸ÃÑ¡ÏîÖ»ÔÚ´´½¨RAID5/50/6/60ʱÓÐЧ£¬´´½¨ÆäËû¼¶±ðµÄLDʱÎÞЧ¡£ |
| Size | RAIDµÄÈÝÁ¿¡£ ˵Ã÷£º ĬÈÏÈ¡×î´óÖµ¡£Èç¹ûÒª´´½¨¶à¸öLD£¬ÐèÒªÔÚ´ËÊÖ¶¯ÉèÖÃArrayµÄÈÝÁ¿¡£ |
| SSD Overprovisioning | ÉèÖÃÔÚ´´½¨ÓÉSSD×é³ÉµÄRAID×éʱ£¬ÊÇ·ñÆôÓÃSSD Over Provisioning¡£ Disabled Enabled ˵Ã÷£º Ö»Óе±RAID×éÓÉSSD×é³Éʱ£¬²ÅÄÜÉèÖøÃÊôÐÔ¡£ ¸ÃÑ¡ÏîÉèÖÃΪ¡±Enabled¡±ºó£¬»áÔÚÊý¾ÝдÈëSSDÖ®Ç°ÖØÐ·ÖÅäËùÓÐʹÓõĿéÀ´ÓÅ»¯SSD£¬¿ÉÒÔ¼Ó¿ì³õʼ»¯µÄËÙ¶È¡£ |
| Acceleration Method | PM8222¿¨ÎÞ»º´æ£¬ |
1.5RAID1µÄÅäÖÃ
Ö÷½çÃæÑ¡Ôñarray configuration

¶øºóÑ¡Ôñcreate array

insÑ¡ÔñÒª×öÕóÁеÄÓ²ÅÌ£¬delÈ¡ÏûÑ¡ÖУ¬Ñ¡ÔñÍê±Ïºó»Ø³µ

raid levelÑ¡Ôñ raid1£¬logical drive name¶ÔÕóÁнøÐÐÃüÃû£¬ÆäËû½¨ÒéĬÈÏ£¬Ñ¡ÔñÍê±Ïºóµã»÷done

²ÎÊý˵Ã÷²Î¿¼RAID0

¿ÉÒԲ鿴ÕóÁÐÒѾ×ö³É¹¦¡£

1.6RAID5µÄÅäÖÃ
Ö÷½çÃæÑ¡Ôñarray configuration

¶øºóÑ¡Ôñcreate array

insÑ¡ÔñÒª×öÕóÁеÄÓ²ÅÌ£¬delÈ¡ÏûÑ¡ÖУ¬Ñ¡ÔñÍê±Ïºó»Ø³µ

raid levelÑ¡Ôñ raid5£¬logical drive name¶ÔÕóÁнøÐÐÃüÃû£¬ÆäËû½¨ÒéĬÈÏ£¬Ñ¡ÔñÍê±Ïºóµã»÷done£¨²ÎÊýÏêϸ˵Ã÷²Î¿¼raid0£©

1.7RAID10µÄÅäÖÃ
Ö÷½çÃæÑ¡Ôñarray configuration

¶øºóÑ¡Ôñcreate array

insÑ¡ÔñÒª×öÕóÁеÄÓ²ÅÌ£¬delÈ¡ÏûÑ¡ÖУ¬Ñ¡ÔñÍê±Ïºó»Ø³µ

raid levelÑ¡Ôñ raid10£¬logical drive name¶ÔÕóÁнøÐÐÃüÃû£¬ÆäËû½¨ÒéĬÈÏ£¬Ñ¡ÔñÍê±Ïºóµã»÷done£¨²ÎÊýÏêϸ˵Ã÷²Î¿¼raid0£©¡£

¿ÉÒԲ鿴µ½raid10ÒѾ×ö³É¹¦

1.8JBODµÄÅäÖÃ
PM8204¿¨Ö§³ÖÈýÖÖ¹¤×÷ģʽ£¬·Ö±ðΪ£º
1.RAID£º¿ØÖÆPGµç¾º¹ÙÍøËùÓеÄRAID¹¦Äܶ¼±»ÆôÓ㬵«Ö±Í¨Å̲»»á±¨Ë͸øOS¡£
2.Mixed£ºRAIDÂß¼Å̺ÍֱͨÅ̶¼»á±¨Ë͸øOS¡£
3.HBA£º¿ØÖÆPGµç¾º¹ÙÍøËùÓеÄRAID¹¦Äܶ¼±»½ûÓ㬿ØÖÆPGµç¾º¹ÙÍøÏÂËùÓÐÓ²Å̾ù±»ÊÓΪֱͨÅÌ¡£
ģʽÐ޸ķ¾¶ÈçÏ£ºÑ¡Ôñconfigure controller setting



˵Ã÷£ºÁ½¸öConnector PortÈç¹û½ÓÔÚͬһ¿éexpanderÉÏ£¬¡±Port CN0 ¡°Ó롱Port CN1 ¡°µÄ¹¤×÷ģʽ±ØÐëÒ»Ö£»Èç¹ûÁ½¸öConnector PortÁ¬½Óֱͨ±³°å£¬¿ÉÒÔ½«¡±Port CN0 ¡°Ó롱Port CN1 ¡°ÉèÖóɲ»Í¬µÄ¹¤×÷ģʽ¡£
1.9Èȱ¸Å̵ÄÅäÖÃ
Ö÷½çÃæÑ¡Ôñarray configuration

Ñ¡Ôñmanage arrays

Ñ¡Ôñctrl+sÅäÖÃÈȱ¸ÅÌ

´Ëʱ¿ÉÒԲ鿴δÅäÖÃÕóÁеÄÓ²ÅÌ£¬°´insÑ¡ÖÐ

°´YÈ·ÈÏ

´ËʱÐèҪѡÔñÅäÖÃÈȱ¸µÄÀàÐÍ£¬Ñ¡ÔñÍê±Ïºóµã»÷done
Dedicated Spare Drive¼´È«¾ÖÈȱ¸
Auto replace drives¼´¾Ö²¿Èȱ¸

Èȱ¸¼´Ìí¼Ó³É¹¦
1.10ɾ³ýÈȱ¸ÅÌ
Ö÷½çÃæÑ¡Ôñarray configuration

¶øºóÑ¡Ôñmanage arrays

´Ë½çÃæ°´del¼´¿É

insÑ¡ÖÐҪɾ³ýµÄÈȱ¸Å̵ã»÷»Ø³µ

¶øºó°´YÈ·ÈÏ£¬É¾³ý³É¹¦

1.11ÅäÖÃÆô¶¯ÅÌ
Ö÷½çÃæÑ¡Ôñarray configuration

1¡¢½«LDÉèÖÃΪÆô¶¯ÅÌ£¬

ÔñÒªÅäÖÃÆô¶¯Å̵ÄÕóÁеã»÷»Ø³µ

´Ë½çÃæctrl+p½«´ËÕóÁÐÉèÖÃΪµÚÒ»Òýµ¼Ïctrl+s½«´ËÕóÁÐÉèΪµÚ¶þÒýµ¼Ïî

ÅäÖÃÍêºóÈçÏÂͼ

2¡¢Ö±Í¨ÅÌÉèÖõÚÒ»Æô¶¯Ïî
Ñ¡ÔñÄØ select boot device

´Ë½çÃæctrl+pÉèÖõÚÒ»Æô¶¯Ïctrl+sÉèÖõڶþÆô¶¯Ïî¡£

ÉèÖÃÍê±ÏºóÈçÏÂͼ

1.12¿ØÖÆPGµç¾º¹ÙÍø³£¼ûÊôÐÔÅäÖÃ
Ö÷½çÃæÑ¡ÏÒå

| ²ÎÊý | ˵Ã÷ |
| Controller Details | ²é¿´¿ØÖÆPGµç¾º¹ÙÍøÏà¹ØµÄ»ù±¾ÐÅÏ¢¡£ |
| Configure Controller Settings | ÉèÖÿØÖÆPGµç¾º¹ÙÍøµÄÏà¹ØÊôÐÔ¡£ |
| Array Configuration | ´´½¨Óë¹ÜÀíArray¡£ |
| Disk Utilities | ²é¿´Óë¹ÜÀí¿ØÖÆPGµç¾º¹ÙÍøµÄÓ²ÅÌ¡£ |
1¡¢controller details

Ôڴ˽çÃæ¿É²éѯRAID¿¨Ðͺţ¬bus number£¬¹Ì¼þ°æ±¾ÒÔ¼°RAID¿¨µ±Ç°Ä£Ê½µÈ¡£

2¡¢configure controller setting

Ñ¡Ôñºó´ò¿ª
| ²ÎÊý | ˵Ã÷ |
| Modify Controller Settings | Ð޸ĿØÖÆPGµç¾º¹ÙÍøµÄÏà¹ØÊôÐÔ¡£ |
| Configure Controller Port Mode | ÉèÖÃRAID¿¨µÄʹÓÃģʽ¡£ |
| Advanced Controller Settings | Ð޸ĿØÖÆPGµç¾º¹ÙÍøµÄ¸ß¼¶ÊôÐÔ¡£ |
| Clear Configuration | Çå³ý¿ØÖÆPGµç¾º¹ÙÍøµ±Ç°µÄËùÓÐÅäÖᣠ|
| Backup Power Source | ³¬¼¶µçÈݵÄ״̬¡£ |
| Manage Power Settings | ¹ÜÀí¿ØÖÆPGµç¾º¹ÙÍøµÄµçÔ´Ä£¿é¡£ |
| BMC Settings | BMCÏà¹ØµÄÉèÖᣠ|
2.1modify controller setting

| ²ÎÊý | ˵Ã÷ |
| Transformation Priority | ÉèÖÃArrayÀ©Õ¹¡¢Âß¼ÅÌÀ©Õ¹¡¢Âß¼ÅÌÇ¨ÒÆ¡¢ArrayÊÕËõ/Ç¨ÒÆµÈ²Ù×÷µÄÓÅÏȼ¶£¬·ÖΪHigh/Medium/LowÈý¸öÑ¡Ïî¡£ ĬÈÏȡֵΪ¡±Medium¡±¡£ ˵Ã÷£º ¸ÃÑ¡ÏîÉèÖÃΪ¡±high¡±Ê±£¬»áÇÀÕ¼IO×ÊÔ´£¬Ó°Ïì¶ÁдIOÐÔÄÜ£¬½¨ÒéÓû§±£³ÖĬÈÏȡֵ¡£ |
| Rebuild Priority | ÉèÖÃÂß¼ÅÌÖØ¹¹µÄÓÅÏȼ¶£¬·ÖΪLow/Medium/Medium High/HighËĸöÑ¡Ïî¡£ |
| Surface Scan Analysis Priority | ÉèÖÃÁ½´ÎÓ²Å̱íÃæÉ¨ÃèµÄʱ¼ä¼ä¸ô£¬Ó²Å̱íÃæÉ¨ÃèÖ÷ÒªÊǼì²éÓ²Å̽¡¿µ×´Ì¬¡£ ¿ÉÑ¡ÏîΪ0~31£¬Ä¬ÈÏֵΪ3£¬Êý×Ö±íʾControllerÔÚÏÂÒ»´ÎSurface Scan Analysis֮ǰµÄÑÓ³Ùʱ¼ä£¬µ¥Î»ÎªÃë¡£0±íʾ½ûÓÃÓ²Å̱íÃæÉ¨Ã蹦ÄÜ¡£ |
| Current Parallel Surface Scan Count | ÉèÖÃͬʱÆô¶¯Ó²Å̱íÃæÉ¨Ãè½ø³ÌµÄÊýÁ¿£¬È¡Öµ·¶Î§Îª1~16£¬Ä¬ÈÏֵΪ1¡£ÉèÖÃΪ1ʱ±íʾ½ûÓÃÓ²Å̱íÃæÉ¨Ã蹦ÄÜ¡£ |
| Spare Activation Mode | ÉèÖÃÈȱ¸Å̵碌îģʽ£¬¿ÉѡģʽÓУº Failure SA£º±íʾӲÅ̹ÊÕÏ»òÀëÏßʱ£¬Ö´ÐÐÈȱ¸¹¦ÄÜ¡£ Predictive SA£º±íʾӲÅ̱ä³ÉPrefailÅÌʱ¾Í¿ªÊ¼Ö´ÐÐÈȱ¸¹¦ÄÜ¡£ |
2.2configura controller port mode


¿ØÖÆPGµç¾º¹ÙÍøµÄ¶Ë¿Úģʽ£¬ÓÐÒÔÏÂÈýÖÖ£º
HBA£º¸ÃģʽÏ£¬Ö§³ÖÓ²ÅÌֱͨ¹¦ÄÜ£¬²»Ö§³Ö´´½¨RAID×é¡£µ±ÓÐRAID×é´æÔÚʱ£¬²»Ö§³ÖÇл»µ½¸Ãģʽ¡£
RAID£º¸ÃģʽÏ£¬Ö§³Ö´´½¨RAID×飬²»Ö§³ÖÓ²ÅÌֱͨ¹¦ÄÜ¡£
Mixed£ºÖ§³ÖÓ²ÅÌֱͨ¹¦ÄÜÓë´´½¨RAID×é¡£
2.3advanced controller setting


| ²ÎÊý | ˵Ã÷ |
| Degraded Mode Performance Optimization | ÉèÖÃÊÇ·ñ´ò¿ª½µ¼¶Ä£Ê½¡£Ä¬ÈÏdisable ʹÄܸÃÑ¡Ïîºó£¬µ±Ò»¸öRAID×éÖÐÓÐÒ»¸ö»ò¶à¸öÓ²Å̳öÏÖ¹ÊÕÏʱ£¬¿ØÖÆPGµç¾º¹ÙÍø½«½øÈë½µ¼¶Ä£Ê½£¬´ËʱRAID×éÄܹ»¼ÌÐøÊ¹Ó㬵«ÊÇÒòΪÐèҪͨ¹ýУÑé²Ù×÷Íê³ÉÒÑËð»µÊý¾ÝµÄÖØ¹¹£¬RAID¼¼ÊõµÄÐÔÄܽ«»á¼«´ó½µµÍ¡£ |
| Physical Drive Request Elevator Sort | ÉèÖÃÊÇ·ñÆôÓõçÌÝÅÅÐòËã·¨´¦ÀíÒ»¸öÎïÀíÅÌÉϵĶà¸öÇëÇó¡£Ä¬ÈÏenable |
| RAID6/60 Alternate Inconsistent Repair Policy | ÉèÖÃÊÇ·ñÆôÓý»Ìæ²»Ò»ÖµÄÐÞ¸´·½·¨¡£ ĬÈÏdisable |
| Maximum Drive Request Queue Depth | ÉèÖÃFirmwareÔÚ¸ø¶¨Ê±¼äÄÚÌá½»¸øÒ»¸öÎïÀíÅ̵Ä×î´óÇëÇóÊý£¬±íʾÎïÀíÅÌÄܹ»½ÓÊܵÄ×î´óÇëÇó¶ÓÁÐÉî¶È¡£¿ÉÉèÖÃΪ£º2¡¢4¡¢8¡¢16¡¢32¡¢Automatic¡£ ĬÈÏAutomatic |
| Monitor and Performance Analysis Delay | ÉèÖþµÏñ²Ù×÷ºÍÐÔÄÜ·ÖÎö²Ù×÷´øÀ´µÄÑÓ³Ùʱ¼ä¡£ ĬÈÏ1-120 ȡֵ·¶Î§£º0-1440 ĬÈÏȡֵ£º60 µ¥Î»£º·ÖÖÓ |
| HDD Flexible Latency Optimization | ÆôÓÃflexible latencyʱ¿Ì±íÄܹ»ÏÞÖÆÓ²Å̵ĸßÑÓʱÇëÇ󣬼´Í¨¹ýÒ»ÕÅflexible latencyʱ¿Ì±í¼Ç¼ÿ¸öÇëÇóµÄÑÓ³Ùʱ¼ä£¬µ±´ïµ½ÑÓʱÉÏÏ޺󣬽«ÓÅÏÈÖ´ÐÐÕâЩÇëÇ󡣿ÉÉèÖÃΪ£º Disabled Low Middle(100ms) High Very High(30ms) Very High(10ms) ĬÈÏdisable |
2.4clear configuration


| Delete All Array Configurations | Çå³ýËùÓÐRAID×éµÄÅäÖÃÐÅÏ¢¡£ |
| Delete RIS on All Physical Drives | Çå³ýÓ²ÅÌÉÏ´æÔڵIJ»ÍêÕûµÄRAID×éÐÅÏ¢¡£ |
2.5backup power source


| ²ÎÊý | ˵Ã÷ |
| Backup Power Status | ³¬¼¶µçÈݵ±Ç°×´Ì¬¡£ changing£º³¬¼¶µçÈÝÕýÔÚ³äµç¡£ charged£º³¬¼¶µçÈݳäµçÍê³É¡£ Not Present£ºÎ´½ÓÈ볬¼¶µçÈÝ¡£ |
2.6manage power setting


| Power Mode | ÉèÖÿØÖÆPGµç¾º¹ÙÍøµÄpower mode¡£ Min Power£º½«staticÉèÖÃÉèΪ×îµÍ¼¶¡£ Balanced£ºstaticÉèÖÃËæÅäÖöø¶¨¡£ Max Performance£º½«staticÉèÖÃÉèΪ×î¸ß¼¶¡£ ˵Ã÷£º ĬÈÏΪ¡±Max Performance¡±¡£ |
| Survival Mode | µ±RAID¿¨µÄζȳ¬¹ýãÐֵʱ£¬Survival Mode½«ÔÊÐí¿ØÖÆPGµç¾º¹ÙÍø½«ËùÓеŦºÄÅäÖÃÉèÖÃΪ×îСֵ£¬Ê¹ÄܸÃģʽºó£¬·þÎñPGµç¾º¹ÙÍø½«¼ÌÐøÔÚÕâÖÖ»·¾³Ï¹¤×÷£¬µ«ÐÔÄÜ¿ÉÄÜ»áϽµ¡£ enabled£ºÆô¶¯¸ÃÌØÐÔ¡£ disabled£º¹Ø±Õ¸ÃÌØÐÔ¡£ |
2.7BMC SETTING


3¡¢Array Configuration


´Ë½çÃæ¿ÉÅäÖò鿴ɾ³ýÕóÁУ¬ÉèÖÃÈȱ¸¡¢Æô¶¯Å̵È
4¡¢Disk Utilities


´Ë½çÃæÑ¡ÔñDevice Information¿É²é¿´Ó²ÅÌÐÅÏ¢

Identify Device¿ÉʹÓö¨Î»µÆ¶¨Î»Ó²ÅÌ
Secure Erase¿É¶ÔδÅäÖÃÕóÁеÄÅ̽øÐа²È«²Á³ý
¶þ¡¢³£¼ûÎÊÌâµÄ¹ÊÕϻָ´
2.1µ¥Å̵ôÏß´¦Àí²½Öè
ÒÔraid5Àµ¥Å̵ôÏߺóraid»á±äΪdegread£¨½µ¼¶£©×´Ì¬£¬Êý¾ÝÈÔ¿ÉÕý³£¶Áд£¬´ËÊ±ÖØÐ°βåÓ²ÅÌ»ò¸ü»»Ó²Å̺󣬻òÓ²ÅÌΪºÃµÄÓ²ÅÌ£¬ÕóÁлá×Ô¶¯Í¬²½£¬Í¬²½Íê³ÉºóÕóÁлá»Ö¸´Õý³£¡£
2.2¶àÅ̵ôÏß´¦Àí²½Öè
ÒÔraid5¾ÙÀý£¬Èç¹ûÕóÁÐÖÐÓÐÁ½¿é»òÒÔÉϵÄÅ̵ôÏߣ¬Ôòraid״̬±äΪOffline£¬´ËʱÊý¾Ý²»¿ÉÓ㬴ËʱÐèÒªÕÒÊý¾Ý»Ö¸´¹«Ë¾½øÐÐÊý¾ÝµÄ»Ö¸´¡£